Equivalent to Parker # Parker V1163-75
Fannteer Compound No.(Supplier of Polymer) VI751342(Solvay) VI751343(Dupont)
Physical properties, press cured 10mins at 170℃, post cured 2hr at 235℃
Test Methods
HD ASTM D2240, Durometer A 75 75
TS(Psi) ASTM D412 2944 2731
EB% 200 193
TEAR:C ASTM D624 28 33
M100% ASTM D412 1089 1009
M200%
M300%
S.P 1.865 1.862
Heat aging test for 70hrs at 250℃
Test Methods
ΔH ASTM D573 0 0
ΔTS0% -9 -12
ΔEB% 61 65
ΔV% -2.8 -3.2
Heat aging test for 70hrs at 275℃
Test Methods
ΔH ASTM D573 0 0
ΔTS0% -43 -54
ΔEB% 85 76
ΔV% -8 -8.9
#101 fluid resistance / 70 hrs at 200℃
Test Methods
ΔH ASTM D471 -4 -5
ΔTS0% -5 -11
ΔEB% -2 -3
ΔV% 12.7 12.2
#7700 fluid resistance / 70 hrs at 200℃
Test Methods
ΔH ASTM D471 -9 -8
ΔTS0% -6 -23
ΔEB% 1 -12
ΔV% 11.4 7.2
Fluid C resistance / 70 hrs at 23℃
Test Methods
ΔH ASTM D471 -5 -3
ΔTS0% -20 -23
ΔEB% -13 -12
ΔV% 3.9 3.5
Compression Set, Method B, Plied, %
Test Methods
ΔCS% B37:175*22HR (ASTM D395) 12 11
ΔCS% B38:200*22HR(ASTM D395) 13 12
Performance at Lower Temperatures
Test Methods
Low temp resistance ASTM D1329 -34 -37
TR-10 ASTM D2137 -24.6 -24.4
Customer Satisfaction Survey